Fan-Cooled Hydraulic Oil Coolers

35 models and product codes · dimensions, pressure ratings and downloadable technical datasheets

Fan-cooled hydraulic oil cooler with aluminum body and integrated fan

About the product

In a hydraulic system, friction in the pump, valves and cylinders heats the oil. When the oil overheats, its flow behavior and lubricating function change, and system efficiency drops. A fan-cooled oil cooler passes the hot oil through a coil with channels and fins, while the integrated fan blows air across the fins. The air never touches the oil, and cooling takes place through heat transfer alone.

For a detailed look at the operating principle, see our article on cooling in hydraulic systems and how a radiator works.

The wide model range, with cooling capacity from 2500 to 40000 kcal/h, aims to meet different needs from small hydraulic units to high flow rate systems. Because the voltage type (DC or AC) and the model group (SF14-2010 ... SF72-2070) can be chosen separately, there is flexibility in both supply and capacity.

Where it is used

It can be used in hydraulic power units, in machines and equipment with a hydraulic circuit, and wherever oil temperature has to be controlled. DC models suit battery-powered mobile equipment, while AC models suit stationary facilities with mains electricity. For an overview of the model family, the article on fan-cooled oil cooler models is helpful.

Technical summary

  • 18 model groups: from SF14-2010 to SF72-2070
  • Every group with DC (12 V, 24 V) and AC (220 V, 380 V) options
  • Maximum flow rate: 40-220 L/min
  • Cooling capacity: 2500-40000 kcal/h
  • Fan diameter: 200-630 mm; large DC models use 2 or 4 fans of 280 mm diameter
  • Maximum working pressure: 15 bar
  • Test pressure: 24 bar
  • PDF datasheet for every model group

Choosing the right model

Model selection depends on flow rate, the heat to be removed and the supply voltage. Please prepare the following information for a quote or technical support:

  • Flow rate of the hydraulic pump (L/min) and system pressure
  • Oil tank volume and your target oil temperature
  • Current oil temperature and ambient temperature
  • Supply: DC 12 V, DC 24 V, AC 220 V or AC 380 V
  • Connection size and the space reserved for the cooler
  • Operating environment and duty (continuous or intermittent)

If you are unsure about the values, it is enough to send us the label data of the machine or hydraulic unit. Reading about why oil cooling systems are necessary can also guide you at this stage.

Pressure values matter in selection too: the working pressure of your system must not exceed the maximum working pressure of the cooler. If sudden pressure spikes occur in the hydraulic line, let us know. If you have it, please also share the type of hydraulic oil you use.

Conclusion and contact

Let us choose the model group that suits your needs together. Send your details through the contact page or call us at 0216 471 47 94; you can get price and lead time information through the same channel.

Technical Details

On narrow screens, scroll the table sideways to see the other columns.

ProductProduct CodeVoltage (V)Maximum Flow (L/min)Maximum Cooling Capacity (kcal/h)Speed (r/min)Fan Diameter (mm)Flow Rate (m³/h)Maximum Working Pressure (bar)Test Pressure (bar) Datasheet Quote
SF14-2010-DCSF142010-121240250032502037001524 PDF Request a quote
SF14-2010-DCSF142010-242440250032502037001524 PDF Request a quote
SF14-2010-ACSF142010-22022040250013002002001524 PDF Request a quote
SF21-2015-DCSF212015-121280600032502258201524 PDF Request a quote
SF21-2015-DCSF212015-242480600032502258201524 PDF Request a quote
SF21-2015-ACSF212015-22022080600014152002681524 PDF Request a quote
SF21-2015-ACSF212015-38038080600014592003091524 PDF Request a quote
SF24-2020-DCSF242020-1212100750032502258201524 PDF Request a quote
SF24-2020-DCSF242020-2424100750032502258201524 PDF Request a quote
SF24-2020-ACSF242020-220220100750014152002681524 PDF Request a quote
SF24-2020-ACSF242020-380380100750014592003091524 PDF Request a quote
SF29-2024-DCSF292024-121212010000300025512401524 PDF Request a quote
SF29-2024-DCSF292024-242412010000300025512401524 PDF Request a quote
SF29-2024-ACSF292024-22022012010000135725010391524 PDF Request a quote
SF29-2024-ACSF292024-38038012010000140425010241524 PDF Request a quote
SF35-2030-DCSF352030-121214013000278028015601524 PDF Request a quote
SF35-2030-DCSF352030-242414013000278028015601524 PDF Request a quote
SF35-2030-ACSF352030-22022014013000137030017571524 PDF Request a quote
SF35-2030-ACSF352030-38038014013000141430016891524 PDF Request a quote
SF39-2035-DCSF392035-121215015500303035023601524 PDF Request a quote
SF39-2035-DCSF392035-242415015500303035023601524 PDF Request a quote
SF39-2035-ACSF392035-22022015015500139135028001524 PDF Request a quote
SF39-2035-ACSF392035-38038015015500141335028421524 PDF Request a quote
SF45-2040-DCSF452040-121216020000290038526301524 PDF Request a quote
SF45-2040-DCSF452040-242416020000290038526301524 PDF Request a quote
SF45-2040-ACSF452040-22022016020000141340037271524 PDF Request a quote
SF45-2040-ACSF452040-38038016020000140740037681524 PDF Request a quote
SF55-2050-DCSF552050-1212180250002780280 x21560 x21524 PDF Request a quote
SF55-2050-DCSF552050-2424180250002780280 x21560 x21524 PDF Request a quote
SF55-2050-ACSF552050-22022018025000139250071041524 PDF Request a quote
SF55-2050-ACSF552050-38038018025000136850071801524 PDF Request a quote
SF72-2070-DCSF722070-1212220400002780280 x41560 x41524 PDF Request a quote
SF72-2070-DCSF722070-2424220400002780280 x41560 x41524 PDF Request a quote
SF72-2070-ACSF722070-220220220400001398630112241524 PDF Request a quote
SF72-2070-ACSF722070-380380220400001414630113041524 PDF Request a quote

Have a question? Write to us.

Send us your machine model and what you need, and we will work out the right radiator together.

Call 0216 471 47 94